DC MCB-FP
  • DC MCB-SP

    The Micron DC MCBs are designed for the highest performance. Devices are designed for direct current (DC) applications like Solar PV, Electric Vehicles, Charging Stations, Battery Storage, and UPS systems.

    Technical Information

    • Standard conformity: IS 60898:2/ IEC 60947
    • Rated Current (In): 6, 10, 16, 20, 25, 32, 40, 50, & 63 A
    • Rated Breaking Capacity : upto 6000A (6 kA)
    • Run Breaking Capacity ICS (%ICU): 75%
    • Rated Voltage (Un): 12V-1000V DC
    • No. of Poles: SP, DP, TP, FP
    • Rated Insulation Voltage (Ui) : 660 V
    • Rated Impulse Voltage (Uimp): 4 kV
    • Energy Limiting Class: Class 3
    • Relative Humidity: ≤ 95%
    • Ambient Temperature(˚C ): -5˚ to 55˚
    • Degree of Protection: IP20
    • Trip Type: Thermal and Magnetic
    • Installation Category: Class III
    • Mounting: Snap-on DIN rail at (35mm x 7.5mm)
    • Connecting Terminals: 25mm²/35mm²

     

     

  • DC MCB-DP

    The Micron DC MCBs are designed for the highest performance. Devices are designed for direct current (DC) applications like Solar PV, Electric Vehicles, Charging Stations, Battery Storage, and UPS systems.

       Technical Information

    • Standard conformity: IS 60898:2/ IEC 60947
    • Rated Current (In): 6, 10, 16, 20, 25, 32, 40, 50, & 63 A
    • Rated Breaking Capacity: up to 6000A (6 kA)
    • Run Breaking Capacity ICS (%ICU): 75%
    • Rated Voltage (Un): 12V-1000V DC
    • No. of Poles: SP, DP, TP, FP
    • Rated Insulation Voltage (Ui) : 660 V
    • Rated Impulse Voltage (Uimp): 4 kV
    • Energy Limiting Class: Class 3
    • Relative Humidity: ≤ 95%
    • Ambient Temperature(˚C ): -5˚ to 55˚
    • Degree of Protection: IP20
    • Trip Type: Thermal and Magnetic
    • Installation Category: Class III
    • Mounting: Snap-on DIN rail at (35mm x 7.5mm)
    • Connecting Terminals: 25mm²/35mm²

  • DC MCB-FP

    The Micron DC MCBs are designed for the highest performance. Devices are designed for direct current (DC) applications like Solar PV, electric vehicles, charging stations, battery storage, and UPS systems.

       Technical Information

    • Standard conformity: IS 60898:2/ IEC 60947
    • Rated Current (In): 6, 10, 16, 20, 25, 32, 40, 50, & 63 A
    • Rated Breaking Capacity: up to 6000A (6 kA)
    • Run Breaking Capacity ICS (%ICU): 75%
    • Rated Voltage (Un): 12V-1000V DC
    • No. of Poles: SP, DP, TP, FP
    • Rated Insulation Voltage (Ui) : 660 V
    • Rated Impulse Voltage (Uimp): 4 kV
    • Energy Limiting Class: Class 3
    • Relative Humidity: ≤ 95%
    • Ambient Temperature(˚C ): -5˚ to 55˚
    • Degree of Protection: IP20
    • Trip Type: Thermal and Magnetic
    • Installation Category: Class III
    • Mounting: Snap-on DIN rail at (35mm x 7.5mm)
    • Connecting Terminals: 25mm²/35mm²

     

Showing all 3 items