MCB_SP
MCB-SPN
MCB-DP
MCB_TP
MCB_TPN
MCB-FP
  • MCB-SP

        Technical Information

    • Standard Conformity: IS/IEC 60898-1:2015
    • Rated Current (In): 0.5-5,6,10,16,20,25,32,40,63 AMP
    • Rated Breaking Capacity: 10000A (10 kA)
    • Rated Voltage (Un): 240V AC
    • Rated Frequency: 50 Hz
    • Dielectric Strength: 2000 V for 1 Minute
    • Rated Insulation Voltage (Ui): 660 V
    • Rated Impulse Voltage (Uimp): 6 kV
    • Energy Limiting Class: Class 3
    • Ambient Temperature(˚C ): -5˚ to 55˚
    • Degree of Protection: IP20
    • Tripping Mechanism: Thermal and Magnetic Type
    • Mounting: Snap-on DIN rail at (35mm x 7.5mm)
    • Connecting Terminals: 25mm²

     

  • MCB-SPN

    Technical Information

    • Standard Conformity: IS/IEC 60898-1:2015
    • Rated Current (In): 6,10,16,20,25,32,40,63 AMP
    • Rated Breaking Capacity: 10000A (10 kA)
    • Rated Voltage (Un): 240V AC
    • Rated Frequency: 50 Hz
    • Dielectric Strength: 2000 V for 1 Minute
    • Rated Insulation Voltage (Ui): 660 V
    • Rated Impulse Voltage (Uimp): 6 kV
    • Energy Limiting Class: Class 3
    • Ambient Temperature(˚C ): -5˚ to 55˚
    • Degree of Protection: IP20
    • Tripping Mechanism: Thermal and Magnetic Type
    • Mounting: Snap on DIN rail at (35mm x 7.5mm)
    • Connecting Terminals: 25mm²

     

  • MCB-DP

        Technical Information

    • Standard Conformity: IS/IEC 60898-1:2015
    • Rated Current (In): 6,10,16,20,25,32,40,63 AMP
    • Rated Breaking Capacity: 10000A (10 kA)
    • Rated Voltage (Un): 240V AC
    • Rated Frequency: 50 Hz
    • Dielectric Strength: 2000 V for 1 Minute
    • Rated Insulation Voltage (Ui): 660 V
    • Rated Impulse Voltage (Uimp): 6 kV
    • Energy Limiting Class: Class 3
    • Ambient Temperature(˚C ): -5˚ to 55˚
    • Degree of Protection: IP20
    • Tripping Mechanism: Thermal and Magnetic Type
    • Mounting: Snap-on DIN rail at (35mm x 7.5mm)
    • Connecting Terminals: 25mm²

     

  • MCB-TP

        Technical Information

    • Standard Conformity: IS/IEC 60898-1:2002
    • Rated Current (In): 6,10,16,20,25,32,40,63 AMP
    • Rated Breaking Capacity: 10000A (10 kA)
    • Rated Voltage (Un): 415 V
    • Rated Frequency: 50 Hz
    • Dielectric Strength: 2000 V for 1 Minute
    • Rated Insulation Voltage (Ui): 660 V
    • Rated Impulse Voltage (Uimp): 6 kV
    • Energy Limiting Class: Class 3
    • Ambient Temperature(˚C ): -5˚ to 55˚
    • Degree of Protection: IP20
    • Tripping Mechanism: Thermal and Magnetic Type
    • Mounting: Snap on DIN rail at (35mm x 7.5mm)
    • Connecting Terminals: 25mm²

     

  • MCB-TPN

    Technical Information

    • Standard Conformity: IS/IEC 60898-1:2002
    • Rated Current (In): 6,10,16,20,25,32,40,63 AMP
    • Rated Breaking Capacity: 10000A (10 kA)
    • Rated Voltage (Un): 415 V
    • Rated Frequency: 50 Hz
    • Dielectric Strength: 2000 V for 1 Minute
    • Rated Insulation Voltage (Ui): 660 V
    • Rated Impulse Voltage (Uimp): 6 kV
    • Energy Limiting Class: Class 3
    • Ambient Temperature(˚C ): -5˚ to 55˚
    • Degree of Protection: IP20
    • Tripping Mechanism: Thermal and Magnetic Type
    • Mounting: Snap on DIN rail at (35mm x 7.5mm)
    • Connecting Terminals: 25mm²

     

     

  • MCB-FP

        Technical Information

    • Standard Conformity: IS/IEC 60898-1:2002
    • Rated Current (In): 6,10,16,20,25,32,40,63 AMP
    • Rated Breaking Capacity: 10000A (10 kA)
    • Rated Voltage (Un): 415 V
    • Rated Frequency: 50 Hz
    • Dielectric Strength: 2000 V for 1 Minute
    • Rated Insulation Voltage (Ui): 660 V
    • Rated Impulse Voltage (Uimp): 6 kV
    • Energy Limiting Class: Class 3
    • Ambient Temperature(˚C ): -5˚ to 55˚
    • Degree of Protection: IP20
    • Tripping Mechanism: Thermal and Magnetic Type
    • Mounting: Snap on DIN rail at (35mm x 7.5mm)
    • Connecting Terminals: 25mm²

     

     

Showing all 6 items